GE P4A Technical Manual page 571

Micom p40 agile single br eaker multi-end current differential ied (non distance)
Table of Contents

Advertisement

P54A/B/C/E
MENU TEXT
Allows user to change password level 2. (8 characters)
Password Level 3
Allows user to change password level 3. (8 characters)
Security Feature
Displays the level of cyber security implemented, 1 = phase 1.
Password
Encrypted password entry cell. Not visible via UI
Password Level 1
Allows user to change Encrypted password level 1. (8 characters)
Not visible via UI
Password Level 2
Allows user to change Encrypted password level 2. (8 characters)
Not visible via UI
Password Level 3
Allows user to change Encrypted password level 3. (8 characters)
Not visible via UI
VIEW RECORDS
This column contains record configuration
Select Event
This selects the required event record. A value of 0 corresponds to the latest event and so on.
Menu Cell Ref
Indicates the type of event
Time & Date
Time & Date Stamp for the event given by the internal Real Time Clock.
Event Text
Up to 32 Character description of the Event (refer to following sections).
Event Value
Up to 32 Bit Binary Flag or integer representative of the Event (refer to following sections).
Select Fault
Setting range from 0 to 14. This selects the required fault record from the possible 15 that may be stored. A value of 0 corresponds to the
latest fault and so on.
Faulted Phase
P54xMED-TM-EN-1
COL
ROW
DEFAULT SETTING
00
D4
AAAA
00
DF
1
00
E1
00
E2
00
E3
00
E4
01
00
01
01
0
01
02
(From Record)
01
03
(From Record)
01
04
01
05
01
06
0
01
07
DESCRIPTION
[ASCII Password (8)]
4 registers for writing 8 character password
Each register contains a pair of characters
Each register is formatted as follows:-
first character of a pair
second character of a pair
Each character is in the Courier range 33 - 122
[ASCII Password (8)]
4 registers for writing 8 character password
Each register contains a pair of characters
Each register is formatted as follows:-
first character of a pair
second character of a pair
Each character is in the Courier range 33 - 122
[Integer]
4 registers for writing encrypted password
Registers can contain any bit pattern.
[ASCII Password (8)]
4 registers for writing encrypted password
Registers can contain any bit pattern.
[ASCII Password (8)]
4 registers for writing encrypted password
Registers can contain any bit pattern.
[ASCII Password (8)]
4 registers for writing encrypted password
Registers can contain any bit pattern.
[ASCII Password (8)]
From 0 to 1023 in steps of 1
[Unsigned Integer (16 bits)]
Menu Cell Ref
[Cell Reference]
Time & Date
[IEC870 Time & Date]
Event Text
[ASCII Text (32)]
Event Value
[Binary Flag (32)/UINT32]
From 0 to 14 in steps of 1
[Unsigned Integer (16 bits)]
Start A
Start B
Appendix B - Settings and Signals
AVAILABLE OPTIONS
B5

Advertisement

Table of Contents
loading

This manual is also suitable for:

P54bP54eP54c

Table of Contents