GE P4A Technical Manual page 731

Micom p40 agile single br eaker multi-end current differential ied (non distance)
Table of Contents

Advertisement

P54A/B/C/E
MENU TEXT
Text label to describe each individual control input. This text is displayed when a control input is accessed by the hotkey menu. It is displayed
in the programmable scheme logic description of the control input
Control Input 30
Text label to describe each individual control input. This text is displayed when a control input is accessed by the hotkey menu. It is displayed
in the programmable scheme logic description of the control input
Control Input 31
Text label to describe each individual control input. This text is displayed when a control input is accessed by the hotkey menu. It is displayed
in the programmable scheme logic description of the control input
GROUP 1: LINE
PARAMETERS
This column contains settings for Line Parameters
Line Length
Setting of the protected line/cable length in km. This setting is available if MEASURE'T SETUP column is selected as Visible in the
CONFIGURATION column and if Distance unit in the MEASURE'T SETUP column is selected as kilometres
Line Length
Setting of the protected line/cable length in miles. This setting is available if Distance unit in the MEASURE'T SETUP column is selected as
miles. Dual step size is provided, for cables/short lines up to 10 miles the step size is 0.005 miles, 0.01 miles otherwise
Line Impedance
Setting for protected line/cable positive sequence impedance in either primary or secondary terms, depending on the Setting Values
reference chosen in the CONFIGURATION column. The set value is used for Fault locator, and for all distance zone reaches calculation if
'Simple' setting mode under GROUP x DISTANCE SETUP is selected.
Line Angle
Setting of the line angle (line positive sequence impedance angle).
kZN Res Comp
Setting of the residual compensation factor magnitude, used to extend the ground loop reach by a multiplication factor of (1+ kZN), is
calculated as ratio:
│kZN│ = (Z0 – Z1)/3Z1
where,
Z1 = positive sequence impedance for the protected line or cable.
Z0 = zero sequence impedance for the protected line or cable.
This setting is a used for Distance protection (when set to simple mode) . If Distance protection is set to Advanced mode, there are individual
settings per Zone in the GROUP x DISTANCE ELEMENTS settings.
kZN Res Angle
Setting of the residual compensation factor angle (in degrees) is calculated as:
ÐkZN = Ð (Z0 – Z1)/3Z1
where,
Z1 = positive sequence impedance for the protected line or cable.
Z0 = zero sequence impedance for the protected line or cable.
This setting is a used for Distance protection (when set to simple mode) . If Distance protection is set to Advanced mode, there are individual
settings per Zone in the GROUP x DISTANCE ELEMENTS settings.
Mutual Comp
To enable (activate) or disable (turn off) the Mutual compensation replica used in both, Distance and Fault locator ground fault loops.
KZm Mutual Set.
Setting of the mutual compensation factor kZm magnitude is calculated as a ratio:
|kZm| = ZM0/3Z1 where,
ZM0 = zero sequence mutual impedance for the protected line or cable.
Z1 = positive sequence impedance for the protected line or cable.
Setting kZm is visible if 'Mutual Comp' is enabled. This setting is a used for fault locator and Distance protection (when set to simple mode) .
If Distance protection is set to Advanced mode, there are individual settings per Zone in the GROUP x DISTANCE ELEMENTS settings.
KZm Mutual Angle
Setting of the mutual compensation angle (in degrees) is calculated as:
P54xMED-TM-EN-1
COL
ROW
DEFAULT SETTING
29
1E
Control Input 30
29
1F
Control Input 31
30
00
30
01
100000
30
02
62.1
30
03
10
30
04
70
30
05
1
30
06
0
30
07
Disabled
30
08
1
30
09
0
DESCRIPTION
[ASCII Text (16 chars)]
From 32 to 163 in steps of 1
[ASCII Text (16 chars)]
From 300 to 1000000 in steps of 10
[Courier Number (metres)]
From 0.05 to 621 in steps of 0.005
[Courier Number (miles)]
From 0.05*v1/I1 to 500*V1/I1 in steps of 0.01*V1/I1
[Courier Number (impedance)]
From 20 to 90 in steps of 1
[Courier Number (angle)]
From 0 to 10 in steps of 0.01
[Courier Number]
From -180 to 90 in steps of 1
[Courier Number (angle)]
Disabled
Enabled
[Indexed String]
From 0 to 10 in steps of 0.01
[Courier Number]
From -180 to 90 in steps of 1
[Courier Number (angle)]
Appendix B - Settings and Signals
AVAILABLE OPTIONS