Usage guidelines
If you set both the traffic-based and time-based logging, the device outputs a session log when
whichever is reached. After outputting a session log, the device resets the traffic counter and restarts
the interval for the session.
Only one traffic-based threshold can take effect. If you set both the byte-based and packet-based
thresholds, the most recent configuration takes effect.
Examples
# Configure the device to output session logs on a per-10-mega-packet basis.
<Sysname> system-view
[Sysname] session log packets-active 10
Related commands
session log enable

session log time-active

session log time-active
Use session log time-active to set the time-based session logging.
Use undo session log time-active to restore the default.
Syntax
session log time-active time-value
undo session log time-active
Default
The device does not output session logs.
Views
System view
Predefined user roles
network-admin
Parameters
time-value: Specifies the interval in minutes. The value range for the time-value argument is 10 to
120 and the value must be integer times of 10.
Usage guidelines
If you set both time-based and traffic-based logging, the device outputs a session log when
whichever is reached. After outputting a session log, the device resets the traffic counter and restarts
the interval for the session.
Examples
# Configure the device to output session logs every 50 minutes.
<Sysname> system
[Sysname] session log time-active 50
Related commands
session log enable
session log bytes-active
session log packets-active