Default
The operating mode is channelized mode.
Views
CE3 interface view
Default command level
2: System level
Parameters
ce3: Sets the CE3 interface to operate in channelized mode.
e3: Sets the CE3 interface to operate in unchannelized mode.
Usage guidelines
Only when the CE3 interface is working in channelized mode can you configure E1 lines.
When the CE3 interface is operating in unchannelized mode, the system automatically creates a serial
interface numbered serial number/0:0 for it. This interface operates at 34.368 Mbps and is logically
equivalent to a synchronous serial interface on which you can make other configurations.
Examples
# Configure interface E3 2/0/0 to operate in unchannelized mode.
<Sysname> system-view
[Sysname] controller e3 2/0/0
[Sysname-E3 2/0/0] using e3
Related commands
controller e3

Basic CT3 interface configuration commands

alarm (CT3 interface)

Use alarm to enable the CT3 interface to detect/send alarm signals.
Use undo alarm to remove the alarm signal detection/sending setting.
Syntax
alarm { detect | generate { ais | febe | idle | rai } }
undo alarm { detect | generate { ais | febe | idle | rai } }
Default
Periodical alarm detection is enabled.
Default
Alarm signal sending is disabled.
Views
CT3 interface view