CPOS interface view
Default command level
2: System level
Parameters
e1-number: Number of an E1 channel on the CPOS interface, in the range of 1 to 63.
master: Sets the clock mode of the E1 channel to master.
slave: Sets the clock mode of the E1 channel to slave.
Usage guidelines
E1 channels on the same CPOS physical interface can use different clock modes, depending on
connected devices. For example, when connected to a SONET/SDH device, an E1 channel should use
the slave clock mode. When directly connected to another device through an optical fiber, the E1
channel must use different modes at the two ends.
Different E1 channels of the same CPOS physical interface are independent of one another in terms of
clock mode.
Examples
# Set the clock mode of E1 channel 1 to master.
<Sysname> system-view
[Sysname] controller cpos 2/0/0
[Sysname-Cpos2/0/0] e1 1 set clock master

e1 set flag

Use e1 set flag to set the overhead bytes for an E1 channel.
Use undo e1 set flag to restore the default E1 channel overhead bytes.
Syntax
e1 e1-number set flag c2 c2-value
undo e1 e1-number set flag c2
e1 e1-number set flag j2 { sdh | sonet } j2-string
undo e1 e1-number set flag j2 { sdh | sonet }
Default
C2 is 0x02 and J2 is cyclic null.
Views
CPOS interface view
Default command level
2: System level
Parameters
e1-number: E1 channel number, in the range of 1 to 63.
c2: Specifies the low-order channel signal tag byte (C2).
218