HP 6600 Command Reference Manual page 178

Table of Contents

Advertisement

Field
BERT state:(stopped, not completed)
Test pattern: 2^7, Status: Not Sync,
Sync Detected: 0
Time: 0 minute(s), Time past: 0 minute(s)
Bit errors (since test started): 0 bits
Bits received (since test started)
Bit errors (since latest sync)
Bits received (since latest sync)
Last clearing of counters
Data in current interval:
Line Code Violations
Far End Block Error
C-Bit Coding Violation
P-bit Coding Violation
Framing Bit Err
Severely Err Framing Secs
C-bit Err Secs
C-bit Severely Err Secs
P-bit Err Secs
P-bit Severely Err Secs
Unavailable Secs
Line Err Secs
Total Data (last 17 15 minute intervals)
T3 2/0/0 CT1 1 is up
Frame-format ESF, clock slave,
loopback not set
FDL Performance Report is disabled
Transmitter is sending RAI
Receiver alarm state is LOF
Description
BERT state: completed, stopped (not completed), or running.
Test pattern in use (such as 2^7, 2^11, 2^15, and QRSS), 2^7 in
this sample output; synchronization state, and the number of
detected synchronizations.
Duration of the BERT test and time that has elapsed.
Number of bit errors received since start of the BERT test.
Number of bits received since start of the BERT test.
Number of bit errors received since last synchronization.
Number of bits received since last synchronization.
Time when counters were last cleared, for example, 14:39:02 UTC
Sat 06/25/2005. If no clearing is performed, "Never" is
displayed.
Statistics spanning the current 15-minute interval, coving the counts
of these items:
Line code violations: BPV, or EXZ.
Far-end block error.
C-bit coding violation.
P-bit coding violation.
Framing bit error.
C-bit erroneous second.
C-bit severely erroneous second, the second during which 44 C-bit
errors occur.
P-bit erroneous second.
P-bit severely erroneous second, the second during which 44 P-bit
errors occur.
Service unavailable second.
Line erroneous second, during which LOS, BPV, EXZ, C-bit, P-bit,
and other errors occur.
Total data spanning the last 17 intervals.
State of T1 line on the CT3 interface: up or down. In this output
sample, T1 line 1 is up.
Information about the T1 line:
Framing format—ESF or SF.
Clock source—slave for the line clock and master for the internal
clock.
Loopback—Local, remote, payload, or not set.
Transmission of PPR in the FDL is disabled. You may enable that with
the t1 set fdl ansi command.
The transmitter of the T1 line is sending RAI signals. When the T1 line
receives LOS, LOF, or AIS signals, it sends RAI signals.
Type of alarm signal that the T1 line can receive: LOS, LOF, AIS, or
RAI.
169

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsr6600

Table of Contents