rai: Remote Alarm Indication (RAI).
Usage guidelines
This command is applicable when the interface operates in CE1 mode.
Examples
# Disable RAI detection on CE1 interface E1 2/0/0.
<Sysname> system-view
[Sysname] controller e1 2/0/0
[Sysname-E1 2/0/0] undo alarm detect ais

cable (CE1 interface)

Use cable to set the cable type for a CE1 interface.
Use undo cable to restore the default.
Syntax
cable { long | short }
undo cable
Default
The long keyword applies.
Views
CE1 interface view
Default command level
2: System level
Parameters
long: Indicates that the attenuation of receiver is –43 dB.
short: Indicates that the attenuation of receiver is –10 dB.
Examples
# Set the cable length matching CE1 interface E1 2/0/0 to short.
<Sysname> system-view
[Sysname] controller e1 2/0/0
[Sysname-E1 2/0/0] cable short

channel-set (CE1 interface)

Use channel-set to bundle timeslots on the CE1 interface into a channel-set.
Use undo channel-set to cancel the bundling.
Syntax
channel-set set-number timeslot-list list
undo channel-set [ set-number ]