Table of Contents

Advertisement

Syntax
using e3 e3-number
undo using e3 e3-number
Default
No serial interface is created for any E3 channel.
Views
CPOS interface view
Default command level
2: System level
Parameters
e3-number: Number of an E3 channel on the current CPOS interface, in the range of 1 to 3.
Examples
# Create a serial interface corresponding to the unframed E3 channel 1 on interface CPOS 2/0/0.
<Sysname> system-view
[Sysname] controller cpos 2/0/0
[Sysname-Cpos2/0/0] using e3 1
[Sysname-Cpos2/0/0] interface serial 2/0/0/1:0
[Sysname-Serial2/0/0/1:0]

using t3

Use using t3 to create a serial interface corresponding to the specified unframed T3 channel.
Use undo using t3 to remove the serial interface for the specified unframed T3 channel.
Syntax
using t3 t3-number
undo using t3-number
Default
No serial interface is created for any T3 channel.
Views
CPOS interface view
Default command level
2: System level
Parameters
t3-number: Number of a T3 channel on the current CPOS interface, in the range of 1 to 3.
Examples
# Create a serial interface corresponding to unframed T3 channel 1 on interface CPOS 2/0/0.
<Sysname> system-view
[Sysname] controller cpos 2/0/0
[Sysname-Cpos2/0/0] using t3 1
248

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsr6600

Table of Contents