Controller E-Cpos; Default - HP 6600 Command Reference Manual

Table of Contents

Advertisement

Views
E-CPOS interface view
Default command level
2: System level
Parameters
master: Configures the E-CPOS interface to use the internal clock.
slave: Configures the E-CPOS interface to use the clock from the line.
Usage guidelines
When an E-CPOS interface is connected to a SONET/SDH device, set the clock mode of the interface to
slave because the clock of a SONET/SDH network is more precise. When two E-CPOS interfaces are
directly fiber-connected, set the two ends to operate in different clock modes.
Examples
# Set the clock mode of interface E-CPOS 2/0/0 to master.
<Sysname> system-view
[Sysname] controller e-cpos 2/0/0
[Sysname-E-Cpos2/0/0] clock master

controller e-cpos

Use controller e-cpos to enter E-CPOS interface view.
Syntax
controller e-cpos e-cpos-number
Views
System view
Default command level
2: System level
Parameters
e-cpos-number: E-CPOS interface number.
Usage guidelines
To configure an E-CPOS interface, enter its interface view first.
Examples
# Enter the view of interface E-CPOS 2/0/0.
<Sysname> system-view
[Sysname] controller e-cpos 2/0/0
[Sysname-E-Cpos2/0/0]

default

Use default to restore the default settings for the E-CPOS interface.