Table of Contents

Advertisement

ft1 idlecode

Use ft1 idlecode to set the line idle code on the T1-F interface. Two types of line idle code are available:
0x7E and 0xFF.
Use undo ft1 idlecode to restore the default.
Syntax
ft1 idlecode { 7e | ff }
undo ft1 idlecode
Default
The line idle code on the T1-F interface is 0x7E.
Views
T1-F interface view
Default command level
2: System level
Parameters
7e: Sets the line idle code to 0x7E.
ff: Sets the line idle code to 0xFF.
Usage guidelines
The line idle code is sent in the timeslots that are not bundled into the logical channels on the interface.
Examples
# Set the line idle code to 0x7E on T1-F interface Serial 2/0/0.
<Sysname> system-view
[Sysname] interface serial 2/0/0
[Sysname-Serial2/0/0] ft1 idlecode 7e

ft1 itf

Use ft1 itf to set the type and the number of interframe filling tags on a T1-F interface. Two types of
interframe filling tag are available: 0x7E and 0xFF.
Use undo ft1 itf to restore the default.
Syntax
ft1 itf { number number | type { 7e | ff } }
undo ft1 itf { type | number }
Default
The interframe filling tag is 0x7E, and the number of interframe filling tags is four.
Views
T1-F interface view
Default command level
2: System level