HP 6600 Command Reference Manual page 119

Table of Contents

Advertisement

0 Ais Alarm Secs, 2087 Los Alarm Secs
52 Slip Secs, 2087 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 2087 Unavail Secs
Table 18 Command output
Field
T1 2/0/0 current state
Description
Basic Configuration
Work mode
Cable type
Frame-format
fdl
Line code
Source clock
Data-coding
Idle code
Itf type
Itf number
Loop back
Alarm State
Receiver alarm state
Transmitter is sending remote alarm.
Pulse density violation detected
SendLoopCode History:
inband-llb-up:0 times, inband-llb-down:0
times.
fdl-ansi-llb-up:0 times, fdl-ansi-llb-down:0 times.
fdl-ansi-plb-up:0 times, fdl-ansi-plb-down:0 times
BERT state:(stopped, not completed)
Test pattern: 2^15, Status: Not Sync, Sync Detected:
0
Time: 0 minute(s), Time past: 0 minute(s)
Description
Physical state of the interface: up or down.
Description about the T1 interface.
Basic configurations of the interface.
Operating mode of the T1 interface, T1 framed in this
example.
Cable type of the T1 interface, 100 ohm balanced in
this example.
Frame format configured on the T1 interface: ESF or
SF.
FDL format: ANSI, ATT, or none.
Line code: AMI or B8ZS.
Source clock used by the interface: master for the
internal clock or slave for the line clock.
Normal or inverted.
0x7E or 0xFF.
Type of interframe filling tag: 0x7E or 0xFF.
Number of interframe filling tags.
Loopback setting on the interface: local, payload,
remote, or not set.
Alarm state.
Type of received alarm: none, LOS, LOF, RAI, or AIS.
Type of transmitted alarm: RAI, or none.
The detected pulse density is incompliant with the
specification.
History of loopback code sending to the peer end,
including the number of transmissions for each type of
code, and the type of the last sent code. (For more
information, see the
BERT state: completed, stopped (not completed), or
running.
Test pattern in use (2^20 or 2^15), 2^15 in this
example; synchronization state, and the number of
detected synchronizations.
Duration of the BERT test and time that has elapsed.
110
sendloopcode
command.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsr6600

Table of Contents