Parameters
feet: Cable length in the range of 0 to 450 feet (0 to 137.2 meters).
Usage guidelines
The cable length in this command refers to the distance between the router and the cable distribution
rack.
Examples
# Set the cable length to 50 feet (15.2 meters) on interface T3 2/0/0.
<Sysname> system-view
[Sysname] controller t3 2/0/0
[Sysname-T3 2/0/0] cable 50

clock (CT3 interface)

Use clock to configure clock source for the CT3 interface.
Use undo clock to restore the default.
Syntax
clock { master | slave }
undo clock
Default
The clock source for the CT3 interface is line clock.
Views
CT3 interface view
Default command level
2: System level
Parameters
master: Adopts the internal clock as the clock source.
slave: Adopts the line clock as the clock source.
Usage guidelines
The clock source is selected depending on the connected remote device. If connected to a transmission
device, the local end uses the line clock. If connected to a CT3 interface on another router, the local end
can use either clock, as long as it is different from the one adopted at the remote end.
Examples
# Use the internal clock as the clock source on CT3 interface T3 2/0/0.
<Sysname> system-view
[Sysname] controller t3 2/0/0
[Sysname-T3 2/0/0] clock master

controller t3

Use controller t3 to enter CT3 interface view.