Alcatel-Lucent 7450 Basic System Configuration Manual page 525

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

2/1 100% 100%
2/2 100% 100%
3/1 100% 100%
3/2 100% 100%
4/1 100% 100%
4/2 100% 100%
5/1 100% 100%
5/2 100% 100%
A 100% 100%
B 100% 100%
==============================================================================
A:ALA-7#
A:ALA-12# show system switch-fabric
sync-if-timing
Syntax
sync-if-timing
Context
show>system
Description
This command displays synchronous interface timing operational information.
Output
The following table describes sync-if-timing output fields.
Basic System Configuration Guide
Label
System Status CPM
A/B
Reference Input Mode
Table 70: System Timing Output
Description
Indicates the present status of the synchronous timing equipment
subsystem (SETS).
Not Present — Only shown on systems without central clocks (7450 ESS-
1)
Master Freerun — The clock is in free-run because it hasn't had a
qualified input reference to lock to
Master Holdover — The clock was locked to an input reference but has
lost all qualified input references and is in holdover.
Master Locked — The clock is locked to an input reference
Acquiring — The clock is training to a qualified input reference.
Revertive
Indicates that for a re-validated or a newly validated reference source
which has a higher priority than the currently selected reference has
reverted to the new reference source.
Non-revertive
The clock cannot revert to a higher priority clock if the current clock goes
offline.
System Management