Parameters
rmon-alarm-id — The rmon-alarm-id is a numerical identifier for the alarm being configured.
interval seconds — The interval in seconds specifies the polling period over which the data is
sample-type — Specifies the method of sampling the selected variable and calculating the value
alarm-type — Specifies the alarm that may be sent when this alarm is first created.
360
The number of alarms that can be created is limited to 1200.
Default
None
Values
1 to 65535
variable-oid oid-string — The oid-string is the SNMP object identifier of the particular variable
to be sampled. Only SNMP variables that resolve to an ASN.1 primitive type of integer
(integer, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. The oid-
string may be expressed using either the dotted string notation or as object name plus dotted
instance identifier. For example, "1.3.6.1.2.1.2.2.1.10.184582144" or
"ifInOctets.184582144".
The oid-string has a maximum length of 255 characters
Default
None
sampled and compared with the rising and falling thresholds. When setting this interval value,
care should be taken in the case of 'delta' type sampling - the interval should be set short
enough that the sampled variable is very unlikely to increase or decrease by more than
2147483647 - 1 during a single sampling interval. Care should also be taken not to set the
interval value too low to avoid creating unnecessary processing overhead.
Default
None
Values
1 to 2147483647
to be compared against the thresholds.
Default
Absolute
Values
absolute — Specifies that the value of the selected variable will
be compared directly with the thresholds at the end of the
sampling interval.
delta — Specifies that the value of the selected variable at the last
sample will be subtracted from the current value, and the
difference compared with the thresholds.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, then a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is
equal to falling or either, a single falling threshold crossing event is generated.
Default
either
Values
rising, falling, either
rising-event rmon-event-id — The identifier of the the rmon>event that specifies the action to
be taken when a rising threshold crossing event occurs.
If there is no corresponding event configured for the specified rmon-event-id, then no
association exists and no action is taken.
If the rising-event rmon-event-id has a value of zero (0), no associated event exists.