Alcatel-Lucent 7450 Basic System Configuration Manual page 370

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

System Command Reference
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
kb-memory-use-warn
Syntax
kb-memory-use-warn rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no kb-memory-use-warn
Context
config>system>thresholds
Description
This command configures memory usage, in kilobytes, for warning thresholds
Default
none
Parameters
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
370
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, then a single rising threshold crossing event is generated. If the first
sample is less than or equal to the falling threshold value and startup-alarm is equal to falling
or either, a single falling threshold crossing event is generated.
Values
rising, falling, either
Default
either
sampled value is greater than or equal to this threshold, and the value at the last sampling
interval was less than this threshold, a single threshold crossing event will be generated. A
single threshold crossing event will also be generated if the first sample taken is greater than
or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
The threshold value represents units of kilobytes.
Default
0
Values
-2147483648 to 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal
to this threshold and the associated startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold value.
The threshold value represents units of kilobytes.
Default
0
Values
-2147483648 to 2147483647
Basic System Configuration Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

77507950

Table of Contents