System Command Reference
Description
This command allows the user to configure a text message for use along with SNMP trap and log event
messages that are sent when the system clears an alarm. The system generates the default message
"Alarm Input Cleared" if no message is configured. The clear-alarm-msg string is included in the log
event when the pin changes to the normal state.
Parameters
message-string — a printable character string, up to 160 characters in length
description
Syntax
description description-string
no description
Context
config>system>alarm-contact-input
Description
This command describes an alarm contact input pin. The description provides an indication of the
usage or attribute of the pin. It is stored in the CLI configuration file and helps the user in identifying
the purpose of the pin. The description is included in the log event when the pin changes state (the
string "Pin x" is used in the log events if no description is configured).
Parameters
description-string — a printable character string, up to 80 characters in length
normal-state
Syntax
normal-state {open | closed}
Context
config>system>alarm-contact-input
Description
This command configures the normal state to be associated with the alarm contact input. When the
system detects a transition from the normal state, an alarm is generated. The alarm is cleared when the
system detects a transition back to the normal state.
Configure the normal state as closed if an external power source is used to power the inputs.
Default
open
Parameters
open — the normal state is identified as open. When the system detects a transition to the closed
closed — the normal state is identified as closed. When the system detects a transition to the open
shutdown
Syntax
[no] shutdown
358
state, an alarm is generated. The alarm is cleared when the system detects a transition back to
the open state.
state, an alarm is generated. The alarm is cleared when the system detects a transition back to