Alcatel-Lucent 7450 Basic System Configuration Manual page 373

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

memory-use-alarm
Syntax
memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no memory-use-alarm
Context
config>system>thresholds
Description
The memory thresholds are based on monitoring the TIMETRA-SYSTEM-MIB sgiMemoryUsed
object. This object contains the amount of memory currently used by the system. The severity level is
Alarm. The absolute sample type method is used.
The no form of this command removes the configured memory threshold warning.
Parameters
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period over which the data is sampled and compared
Basic System Configuration Guide
sampled value is greater than or equal to this threshold, and the value at the last sampling
interval was less than this threshold, a single threshold crossing event will be generated. A
single threshold crossing event will also be generated if the first sample taken is greater than
or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
The threshold value represents units of bytes.
Default
0
Values
-2147483648 to 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal
to this threshold and the associated startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold value.
The threshold value represents units of bytes.
Default
0
Values
-2147483648 to 2147483647
with the rising and falling thresholds.
The threshold value represents units of bytes.
Values
1 to 2147483647
System Management
373

Advertisement

Table of Contents
loading

This manual is also suitable for:

77507950

Table of Contents