Alcatel-Lucent 7450 Basic System Configuration Manual page 365

Ethernet service switch /service router /extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

alarm-type — Specifies the alarm that may be sent when this alarm is first created.
Configuration example
cflash-cap-alarm-pct cf1-A: rising-threshold 70 falling-
threshold 60 interval 120 rmon-event-type both start-alarm rising
cflash-cap-warn
Syntax
cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command.
The severity level is warning. Both a rising and falling threshold can be specified. The no form of this
command removes the configured compact flash threshold warning.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
Basic System Configuration Guide
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is
equal to falling or either, a single falling threshold crossing event is generated.
Values
rising, falling, either
Default
either
Values
cf1:, cf1-A:, cf1-B:, cf2:, cf2-A:, cf2-B:, cf3:, cf3-A:, cf3-B:
sampled value is greater than or equal to this threshold, and the value at the last sampling
interval was less than this threshold, a single threshold crossing event will be generated. A
single threshold crossing event will also be generated if the first sample taken is greater than
or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal to the falling-
threshold value.
The threshold value represents units of 512 bytes.
Values
-2147483648 to 2147483647
Default
0
System Management