SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition
Conditions
Group
Syntax
Arguments
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:DATa:DIRection
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual
:SEARCH:SEARCH1:TRIGGER:A:BUS:B2:LIN:IDENTIFIER:VALUE
"XXXXXX";
:SEARCH:SEARCH1:TRIGGER:A:BUS:B1:LIN:ERRTYPE SYNC;
:SEARCH:SEARCH1:TRIGGER:A:BUS:B2:LIN:ERRTYPE SYNC;
:SEARCH:SEARCH1:TRIGGER:A:BUS:B1:PARALLEL:VALUE
"XXXXXXXXXXXXXXXX";
:SEARCH:SEARCH1:TRIGGER:A:BUS:B2:PARALLEL:VALUE
"XXXXXXXXXXXXXXXX";
:SEARCH:SEARCH1:TRIGGER:A:BUS:SOURCE B1
Sets or returns the search condition for a CAN trigger search.
search number and
B<x>
This command requires a DPO2AUTO application module.
Search
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition
{SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS|ERROR}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition?
specifies a search based on the start of frame.
SOF
specifies a search based on the frame type.
FRAMEtype
specifies a search based on the frame identifier.
IDentifier
specifies a search based on the frame data.
DATA
specifies a search based on the frame identifier and data.
IDANDDATA
specifies a search base on the end of frame.
EOF
specifies a search based on the missing ACK field.
ACKMISS
specifies a search based on a bit stuffing error.
ERROR
Sets or returns the CAN search to be valid for Read, Write, or Either condition if
the criteria is IDentifier.
number. This only applies if the search condition is IDentifier.
Commands Listed in Alphabetical Order
is the bus number.
is the search number and
SEARCH<x>
is the
SEARCH<x>
is the bus
B<x>
2-247
Need help?
Do you have a question about the MSO2024B and is the answer not in the manual?