Tektronix MSO2024B Programmer's Manual page 105

Mso2000b series; mso2000 series; dpo2000b series; dpo2000 series
Hide thumbs Also See for MSO2024B:
Table of Contents

Advertisement

Conditions
Group
Syntax
Arguments
Examples
BUS:B<x>:SPI:FRAMING
Conditions
Group
Syntax
Arguments
Examples
BUS:B<x>:SPI:IDLETime
Conditions
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual
This command requires a DPO2EMBD application module.
Bus
BUS:B<x>:SPI:DATA:SIZe <NR1>
BUS:B<x>:SPI:DATA:SIZe?
specifies the number of bits per word.
<NR1>
BUS:B1:SPI:DATA:SIZe 16
BUS:B1:SPI:DATA:SIZe?
indicating that the data size is 8 bits.
Sets or returns the type of SPI framing.
This command requires a DPO2EMBD application module.
Bus
BUS:B<x>:SPI:FRAMING {SS|IDLEtime}
BUS:B<x>:SPI:FRAMING?
specifies framing by SS (non 2-wire).
SS
specifies framing by Idle Time (2-wire).
IDLEtime
BUS:B1:SPI:FRAMING SS
BUS:B1:SPI:FRAMING IDLETIME
indicating that the SPI framing type is set to IDLETIME.
IDLETIME
Sets or returns the SPI bus idle time in seconds for the specified SPI bus.
This command requires a DPO2EMBD application module.
Commands Listed in Alphabetical Order
sets the data size to 16.
might return
BUS:B1:SPI:DATA:SIZe 8
sets the SPI framing type to SS.
might return
BUS:B1:SPI:FRAMING
2-89