Fucntional Description

6.1.5 Description of In-Parameter

In. 0
Inverter type
Adr.
2C00h
The inverter type is represented as hexadecimal number. The bits have following significance:
hex
1
binary
0 0 0 1 1 1 1 0 1 1 0 1 1 1 0 1
In. 1
Rated inverter current
Adr.
2C01h
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.
In. 4
Software version
Adr.
2C04h
The software version-number of the Host-CPU and the control hardware is encoded in this parameter.
1. digit:
2. and 3. digit:
4. digit:
Chapter
Section
Page
6
1
16
min
max
-
-
E
D
min
max
0
?
min
max
0
FFFF
C = F4-F
Software version ( e.g. 14 = 1.4 )
Special version ( 0 = Standard)
Date
Name: Basis
16.03.99
KEB COMBIVERT F4-F
1
D
Display
bit 0:
Voltage class
0 = 230V
bit 1-5:
Unit size
z.B. 01110 = 14
bit 6-8:
Control type
000 = 0A.S4
bit 10:
free (default=1)
bit 11-12:
Maximal operating frequency
01 = 8kHz
bit 9, 13-15: Housing size
0000 = G
0001 = D
0010 = H
0011 = E
0100 = K
0,1
1
In-Parameter
default
hex
-
1 = 400V
011 = 0C.F4
11 = 16kHz
0110 = L
1000 = M
1010 = N
1100 = R
1110 = free
default
A
LTK
default
-
-
©
KEB Antriebstechnik, 1999