KEB COMBIVERT F4-F Applications Manual page 175

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Parameter Sets
Parameter set source (Fr.2)
Parameter set setting (Fr.4 )
Binary-coded set selection
Fig. 6.8.3.b Binary-coded parameter set selection
I4
I3
I1
1
0
2
2
0
0
0
0
0
1
0
2
0
0
2
1
4
0
0
4
0
1
4
2
0
4
2
1
©
KEB Antriebstechnik, 1999
All Rights reserved
As shown in Fig. 6.8.3 with Fr.2 it is defined whether the parameter set selection is
enabled or disabled by keaboard/bus (Fr.4) of by way of terminal strip.
Fr.2
Function
0
Set selection disabled; set 0 always active
1
Set selection by keyboard/bus with Fr.4
2
Set selection binary-coded by way of terminal strip
3
Set selection input-coded by way of terminal strip
This parameter can be written by keyborad or by bus. The desired parameter set
(0...7) is entered directly as value.
The adjustment by way of terminal strip can be done binary-coded or input-coded.
The inputs are defined for set selection with the parameters di.3...di.10 „value 1".
For binary-coded set selection
-
maximal 3 of the internal or external inputs may be programmed for set selection
(2
3
=8 sets) in order to avoid set selection erors.
-
the significance of the inputs programmed for set selection rises (I1 < I2 < I3 <
I4 < I5 < I6 < IA < IB < IC < ID)
Example 1: Set 0...8 shall be selected with 3 inputs (I1, I3 and I4).
1.)
Adjust parameter di.3, di.5 and di.6 to value „1"
Parameters di.4, di.7...di.10 must be set to ≠ 1
2.)
3.)
Adjust Fr.2 to value „2" (set selection binary-coded by way of terminal strip)
Input
Set
0
1
2
3
4
5
6
7
Set 5
Set 4
Set 3
Set 2
Set 1
Set 0
Name: Basis
KEB COMBIVERT F4-F
Functional Description
ID
IB
I4
I2
I1
ANTRIEBSTECHNIK
Date
Chapter
Section
6
7
08.03.99
6
Page
5
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF