KEB COMBIVERT F4-F Applications Manual page 275

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Network Hardware
Connection
Optical Fibre BUS
00.F4.028-1009
The installation is possible with optical fibre
operators and/or units with optical fibre interface
and interface operator.
Connection of Optical
Fibre Interface to PC
(or Master)
Permissible Line Length
between the Users
©
KEB Antriebstechnik, 1998
All Rights reserved
Master
Slave
00.F4.010-A009
START
ENTER
FUNC.
F/R
SPEED
STOP
9-pole Sub-D Socket
(Optical Fibre
Interface Slave)
Cable damping
0,3 dB
0,2 dB
0,1 dB
Tested transfer rate ➯ 115 kBaud
Switch position A must be used for an ambient temperature > 35 °C.
Name: Option
LWL - BUS
Number of users = 1 ... 239
Slave
Slave
00.F4.010-A009
00.F4.028-1008
START
ENTER
FUNC.
F/R
SPEED
STOP
00.F4.010-1009
START
ENTER
F/R
STOP
PC
2
3
5
Switch position A
0 ... 42 m
0 ... 63 m
0 ... 127 m
Networks
ANTRIEBSTECHNIK
Slave
00.F4.028-1008
00.F4.010-1009
START
FUNC.
ENTER
FUNC.
SPEED
F/R
SPEED
STOP
9-pole Sub-D Connector
Optical Fibre
2
Interface Master
3
(Operator)
7
Housing (PE)
Switch position B
3 ... 55 m
3 ... 83 m
6 ... 167 m
Date
Chapter
Section
11
1
05.01.99
11
Page
7
7

Hide quick links: