KEB COMBIVERT F4-F Applications Manual page 153

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Motor Data and Controller Adjustment
Fig. 6.5.8.a Output voltage stabilization
dS.10 = 1...500 V
501 = off (default)
Example: dS.10 = 230V
Fig. 6.5.8.b Example: Deceleration of a drive for high-inertia load from 80 Hz (controlled)
Actual speed
DC-link voltage
Motor voltage
Load
©
KEB Antriebstechnik, 1999
All Rights reserved
U
250 V
dS.10 = 230V
CP.17 = 230 V
190 V
no boost adjusted
with output voltage
stabilization
Name: Basis
KEB COMBIVERT F4-F
Functional Description
/U
N
A
U
bei U
A
U
bei U
A
U
bei U
A
U
bei U
A
dr.3 = 50Hz
CP.5 = 50 Hz
Actual speed
DC-link voltage
Motor voltage
Load
ANTRIEBSTECHNIK
= 250V stabilized
N
= 250V non-stabilized
N
= 190V stabilized
N
= 190V non-stabilized
N
U
= system voltage
N
U
= output voltage
A
f
without output voltage
stabilization
Date