KEB COMBIVERT F4-F Applications Manual page 52

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Operation
Behaviour at External Fault
Chapter
Section
Page
4
3
12
This parameter determines how the drive reacts to an external error (digital Input I3).
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
Note:
Value
Error / Status
massage
0
E.EF
1
A.EF
2
A.EF
3
A.EF
4
A.EF
5
A.EF
6
none
Quick stop
Date
Name: Basis
15.12.98
KEB COMBIVERT F4-F
0...6
1
0
________
ENTER-Parameter
Response of the drive
modulation immediately switched off
! To restart remove error and activate Reset !
quick stop / modulation switched off after speed 0 is
reached
! To restart remove error and activate Reset !
quick stop / holding tourqe at speed 0
! To restart remove error and activate Reset !
modulation immediately switched off
! Automatic restart, when error is no longer present
!
quick stop / modulation switched off after speed 0 is
reached
! Automatic restart, when error is no longer present
!
quick stop / holding tourqe at speed 0
! Automatic restart, when error is no longer present
!
no effect on the drive
! Fault is ignored !
⇒ ⇒ ⇒ ⇒ ⇒
deceleration at the torque limit (CP.9)
©
CP - Parameter
KEB Antriebstechnik, 1998