KEB COMBIVERT F4-F Applications Manual page 60

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Operation
Speed Regulation on/off
Boost
Chapter
Section
Page
4
3
20
In CP .32 you can select whether the inverter operates open-loop or closed loop.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
0
=
open-loop
1
=
closed-loop (field-oriented control)
During open-loop operation the torque limits, levels and displays do not have a function.
All parameters, that access these values, either do not have a function or have a
restricted function. This is described in the individual parameters.
Caution !
open !
The voltage increase for the lower speed range is adjusted with the boost, which
results in a higher torque in the lower range. During closed-loop operation this
parameter does not have a function!
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
U
100
CP.33
When the motor is driven during continuous operation at a slow
speed and the voltage is too high, the motor may overheat!
Date
Name: Basis
15.12.98
KEB COMBIVERT F4-F
0...1
________
(U/f-curve)
Only switch over when control release is
Torque jumps may occur if not observed.
0...25,5
________
[%]
A
CP.28
CP - Parameter
1
0
%
0,1
%
2
%
%
f [Hz]
©
KEB Antriebstechnik, 1998
All Rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents