Selection Of Parameter Sets - KEB COMBIVERT F4-F Applications Manual

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Functional Description
Error message „nco"
Adjustment of source and
target set by keyboard
(Fr.1 / Fr.9)
6.7.3 Selection of Para-
meter Sets
Fig. 6.8.3.a Principle of parameter set selection
Set selection deactivated
always Set 0 activ
Fr.3 Parameter set lock
0..7 (Value 0..255)
Chapter
Section
Page
6
7
4
If error message „nco" is displayed, it can have the following causes:
Cause
Attempt of copying the default set
(def) into the just active set.
During initialization (init) the control
release was not disabled.
Source and target set are identical.
The current set (A) is selected as
target set.
At bus operation two parameters are responsible for the copying of parameter sets.
Fr.9 defines the target set. Fr.1 defines the source parameter set and starts the copying
process. These parameters are not visible by way of keyboard.
Fr.4 with
Keyboard / Bus
Parameter set 0...7
Parameter set
Date
Name: Basis
KEB COMBIVERT F4-F
08.03.99
Remedy
Open control release or activate another
parameter set.
Open control release or trigger error.
Change either source or target set.
Select valid value (0...7) as target set.
I1...ID (max.3)
I1 < I2 <....<ID
Set 0..7
2
1
0
2
2
2
7
Terminals
binary coded
1
2
0
3
Fr.2
Is
selected
Error message
yes
Set
E.SEt
locked?
no
Aktual
Parameter Sets
I1...ID (max.7)
I1 has priority
Set 0..7
6
5
4
3
2
1
Terminals
input coded
©
KEB Antriebstechnik, 1999
All Rights reserved