Operation
Torque Level output D1
Speed Level output D2
Rated Motor Power
Rated Motor Speed
Rated Motor Current
Rated Motor Frequency
Chapter
Section
Page
4
3
18
Defines the torque level for the digital output D1. During open-loop operation (CP .32
= 0) the value for the motor torque is set at 0.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
max. Tolerance
(In the field weakening range larger tolerances are possible, also see reference on
page 4)
Defines the speed level for the digital output D2.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
The rated motor power of the connected motor must be adjusted in CP .25.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
The rated motor speed of the connected motor must be adjusted in CP .26.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
The rated current of the connected motor must be adjusted in CP .27.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
The rated frequency of the connected motor must be adjusted in CP .28.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
Date
Name: Basis
15.12.98
KEB COMBIVERT F4-F
0...2000
0,1
________
approx. ±30 %
in the base speed range
0...9999,5
0,5
________
0,01...75
0,01
dependent on size
________
100...9999,5
dependent on size
________
dependent on size
0,1
dependent on size
________
20...300
dependent on size
________
CP - Parameter
Nm
Nm
0
Nm
Nm
rpm
rpm
0
rpm
rpm
kW
kW
kW
rpm
1
rpm
rpm
A
A
Hz
1
Hz
Hz
©
KEB Antriebstechnik, 1998
All Rights reserved