KEB COMBIVERT F4-F Applications Manual page 93

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

ru-Parameter
ru.25 Peak apparent current
Adr.
2019h
ru.25 allows the detection of short-time peaks of the motor current within an operating cycle. For that the highest
detected value of ru.9 is stored. The peak value memory is cleared by pressing the keys UP or DOWN or by bus by
writing any chosen value to the address of ru.25. A disconnection of the inverter also results in a clearing of the
memory.
ru.26 Actual speed master
Adr.
201Ah
Shows the actual motor speed of the drive connected to the encoder interface 2 (X5).
Precondition: Encoder line number (dr.30) and rotation of encoder (dr.34) are adjusted correctly.
ru.27 Angular deviation
Adr.
201Bh
Display of the angular displacement between setpoint position and actual position in the positioning and synchronous
operation.
ru.28 Speed deviation
Adr.
201Ch
Display of speed droop between actual speed of the master and actual speed of the slave (independent of rotation
direction).
Positive speed values: The master drive rotates faster than the slave drive.
Negative speed values: The slave drive rotates faster than the master drive.
ru.29 Heat sink temperature
Adr.
201Dh
ru.29 shows the actual heat sink temperature of the inverter.
©
KEB Antriebstechnik, 1999
All Rights reserved
min
max
0
unit-dependent
min
max
-9999,5
9999,5
min
max
-360,0
360,0
min
max
-9999,5
9999,5
min
max
0
100
Name: Basis
KEB COMBIVERT F4-F
Functional Description
A
0,1
rpm
0,5
°
0,1
rpm
0,5
°C
1
Date
16.03.99
ANTRIEBSTECHNIK
default
-
default
-
default
-
default
-
default
-
Chapter
Section
Page
13
6
1
13
6

Hide quick links:

Advertisement

Table of Contents
loading