KEB COMBIVERT F4-F Applications Manual page 160

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Functional Description
Motor Connection (dr.52)
Adaption factor (dS.15)
Flux Controller / Mode (CS.22)
Chapter
Section
Page
6
5
14
Adjustment of the connection (star/delta).
dr.52
0
1
Display of the adaption intervention.
Range of values: off (adaption off)
With CS.22 the flux controller is changed to max. voltage control. Operation in the
field
weakening range is stabilized by this way. This parameter must only be activated
when the motor parameter adaption is active. The output voltage in the field weakening
range is limited to 100% and a critical increasing is prevented by this.
CS.22
Flow controller / mode
0
Flow controller on (factory setting)
1
Max.voltage controller on (adjustment by Kp)
Date
Name: Basis
KEB COMBIVERT F4-F
11.05.99
Motor Data and Controller Adjustment
Motor connection
star
delta (factory setting)
0,1% ... 100,0% (no intervention)
©
KEB Antriebstechnik, 1999