Profile Of Speed Precontrol (Pd.3, Pd.5 - KEB COMBIVERT F4-F Applications Manual

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Positioning Module
6.11.11 Gear Factor for
Encoder Input 2
(Pc.17)
6.11.12 Profile of Speed
Precontrol (Pd.3,
Pd.5...Pd.7)
Fig. 6.11.11 Profile of speed precontrol
SP.8/SP.9
Pd. 7
©
KEB Antriebstechnik, 1999
All Rights reserved
When the position encoder at encoder input 2 is connected to the motor by way of a
gear unit, the gear ratio must be adjusted here (encoder at encoder input 1 must
always be connected directly to the motor shaft).
Pc.17
With these parameters it is possible to assign an individual speed precontrol profile
to every position. However, the preadjusted values can only be kept if neither general
torque limits nor the maximum speed (SP .8 ( SP .9) are exceeded.
Pd. 3
Pd. 3
Pd. 5
Pd. 5
Pd. 6
As shown in Fig. 6.11.11 it must be observed that the setting of SP .8 / SP.9 is larger
than the setting of Pd.7 + Pd.3.
Name: Basis
KEB COMBIVERT F4-F
Functional Description
Setting range:
1,00 ... 250,00
Resolution:
0,01
Pd. 5
ANTRIEBSTECHNIK
A change of the parameter
values is only possible in
„noP" state.
Pd. 5
Pd. 6
Date
Chapter
Section
6
11
17.06.99
6
Page
9
9