KEB COMBIVERT F4-F Applications Manual page 55

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

CP - Parameter
Function Output A1
©
KEB Antriebstechnik, 1998
All Rights reserved
Defines which variable is displayed on analog output 1 (terminal X2.18).
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
Note:
Value Output Variable
0
Actual speed
1
Motor apparent current
2
Actual torque
3
DC-bus voltage
4
Speed reference (CP.6)
5
Control difference
(speed controller)
6
Set torque
7
Modulation depth
8
Position
9
Speed in front of ramp
10
REF1 output
n
: Rated-Rotating Field Speed
fn
M
: Rated Torque
N
I
: Rated-Motor Apparent Current
SN
During open-loop operation (CP.32 = 0) the analog output A1
has no function with the values 2,5, and 6.
Name: Basis
KEB COMBIVERT F4-F
Operation
0...10
1
2
________
ENTER-Parameter
Value Range when CP.19 = 1
-2 • n
... +2 • n
fn
0 ... 2 • I
SN
-2 • M
... +2 • M
N
0 ... 1000 V
-2 • n
... +2 • n
fn
-2 • n
... +2 • n
fn
-2 • M
... +2 • M
N
0...100 %
- in the CP-Mode no funktion-
-2 • n
... +2 • n
fn
-10V...+10V
Date
15.12.98
ANTRIEBSTECHNIK
^
=
-10V ... +10V
fn
^
=
0 ... +10V
^
=
-10V ... +10V
N
^
=
0 ... +10V
^
=
-10V ... +10V
fn
^
=
-10V ... +10V
fn
^
=
-10V ... +10V
N
^ =
0... 10V
^ =
-10V ... +10V
fn
^ =
-10V...+10V
Chapter
Section
Page
15
4
3
15
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents