KEB COMBIVERT F4-F Applications Manual page 104

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Functional Description
Control terminal strip X2
Typical circuits
Chapter
Section
Page
6
2
4
Terminal Designa- Function
No.
tion
12
CRF
13
COM
14
REF 1 +
15
REF 1 –
16
REF 2 +
17
REF 2 –
1. Setpoint setting: External differential voltage without internal reference potential.
Fig. 6.2.2
Connection without internal reference potential
Date
Name: Basis
KEB COMBIVERT F4-F
17.09.98
+10 V reference voltage
Earth for analog inputs/outputs
Analog setpoint setting
Programmable analog input
Internal resistance Ri = 40 kΩ
12
13
14
15
CRF COM REF1 REF1 REF2 REF2
+
source of
external
differential
votlage
Analog In- and Outputs
+10V (+/- 3%) ; max. 4 mA
Differential voltage input
rpm / Resolution: 12 Bit
Ri = 24 kΩ / 40 kΩ
scan time: 2ms
At fast setpoint input and
torque control: 128µs
(see chapter 6.5.18)
16
17
+
source of
external
differential
voltage *
)
*
)
also refer to parameter
AN.13 in Chapter 6.4
©
KEB Antriebstechnik, 1998