Deceleration Time
Torque Limit
Chapter
Section
Page
4
3
8
Defines the time needed to decelerate from 1000 to 0 rpm. The actual deceleration
time is proportional to the speed change (D n).
Adjustment Range:
Resolution:
Factory setting:
Customer setting
n [rpm]
∆ t
1000
800
∆ n
300
0
0,5
1
CP.8
Example:
The drive should decelerate from 800 rpm to 300 rpm in 1 s.
∆ ∆ ∆ ∆ ∆ n
= 800 rpm - 300 rpm = 500 rpm
∆ ∆ ∆ ∆ ∆ t
= 1 s
∆ t
CP.8 =
x 1000 rpm
∆ n
Adjusts the maximum permissible torque of the drive. The parameter can be influenced
by the analog torque limitation. During open-loop operation (CP.32 = 0) this
parameter has no function.
Adjustment Range:
Resolution:
Factory setting:
Customer setting
max. tolerance: approx. ±20 % in base speed range
(In the field weakening range larger tolerances are possible, also see reference on
page 4)
M [Nm]
CP.9
0
Date
Name: Basis
15.12.98
KEB COMBIVERT F4-F
0...320
0,01
2,0
________
∆ n
∆ t
CP.8 =
t [s]
1,5
2
1 s
=
500 rpm
0...5 x M
N
0,1
dependent on size
________
Analog Limiting
Terminals X2.16 / X2.17
! only when CP.36 = 5 !
U [V]
(REF 2)
+10
CP - Parameter
s
s
s
s
speed change
deceleration for ∆ n
∆ t
x 1000 rpm
∆ n
x 1000 rpm = 2 s
Nm
Nm
Nm
©