Functional Description

6.1 Operating and Unit Datas

6.1.1 Summary of
ru-Parameter
ru. 0 Inverter state
ru. 1 Actual speed display
ru. 2 Actual torque display
ru. 4 Set speed display
ru. 7 Actual inverter utilization
ru. 8 Peak inverter utilization
ru. 9 Apparent current
ru. 10 Active current
ru. 11 Actual DC voltage
ru. 12 Peak DC voltage
ru. 14 Input terminal state
ru. 15 Output terminal state
ru. 16 Internal input state
ru. 17 Internal output state
ru. 18 Actual parameter set
ru. 20 Speed REF display
6.1.2 Summary of
In-Parameter
In.
0 Inverter type
In.
1 Rated inverter current
In.
4 Software version
In.
5 Software date
In.
6 Configfile no.
In.
7 Serial number (date)
In.
8 Serial number (counter)
In.
9 Serial number (Ackn.-No. high)
In. 10 Serial number (Ackn.-No. low)
In. 11 Customer number (high)
In. 12 Customer number (low)
©
KEB Antriebstechnik, 1999
All Rights reserved
The parameter groups „ru" and „In" are described in this chapter. They serve for
the operational monitoring, error analysis and evaluation as well as for the unit
identification.
The ru- (run) parameter group represents the multimeter of the inverter. Here
speeds, currents, voltages etc. are displayed which allow a conclusion on the
operating condition of the drive. This can be especially helpful for the start-up of a
plant or with regard to trouble shooting. Following parameters are available:
ru. 22 Ref1 display
ru. 23 Ref2 display
ru. 24 OL counter display
ru. 25 Peak apparent current
ru. 26 Actual speed master
ru. 27 Angular deviation
ru. 28 Speed deviation
ru. 29 Heat sink temperature
ru. 31 Power on counter
ru. 32 modulation on counter
ru. 35 Actual position sign
ru. 36 Actual position high
ru. 37 Actual position low
ru. 38 Set position sign
ru. 39 Set position high
ru. 40 Set position low
The In- (Information) parameter group includes data and information about the
identification of the hardware and software as well as to the type and number of
the errors that occurred. Following parameters are available:
In. 40 Last error
In. 41 Error counter OC
In. 42 Error counter OL
In. 43 Error counter OP
In. 44 Error counter OH
In. 45 Error counter watchdog
In. 54 Software version DSP
In. 55 Software date DSP
In. 56 Feedback-system channel 1
In. 57 Feedback-system channel 2