Fucntional Description
In.40 Last error
Adr.
2C28h
In.40 shows the error that occurred last, E. UP is not stored. The error messages are described under parameter ru.0.
In.41 Error counter OC
In.42 Error counter OL
In.43 Error counter OP
In.44 Error counter OH
In.45 Error counter watchdog
Adr.
s.a.
The error counters (for E.OC, E.OL, E.OP , E.OH (E.dOH), E.buS) state the total number of the different error types that
occurred. The maximum value is 255.
In. 54 Software version DSP
Adr.
2C36h
The software version-number of the control processor and the control hardware is encoded in this parameter.
1. digit:
2. and 3. digit:
4. digit:
Chapter
Section
Page
6
1
18
min
max
0
63
2C29h
2C2Ah
2C2Bh
2C2Ch
2C2Dh
min
max
0
255
min
max
0
FFFF
C = F4-F
Software version ( e.g. 14 = 1.4 )
Special version ( 0 = Standard)
Date
Name: Basis
16.03.99
KEB COMBIVERT F4-F
default
-
-
1
default
-
1
0
default
-
1
-
©
KEB Antriebstechnik, 1999
All Rights reserved