3. Fault signals
The reaction of the drive to the fault signals listed below (abnormal stopping) can be determined with parameter Pn.20
and Pn.23...Pn.26:
Display
Bus
Meaning
A.EF
90
Abnormal Stopping
A.buS
93
Abnormal Stopping
A.PrF
94
Abnormal Stopping
Prohibited Rotation
Forward
A.Prr
95
Abnormal Stopping
Prohibited Rotation
Reverse
A.dOH
96
Abnormal Stopping
Drive Overheat
A.OH
99
Abnormal Stopping
Overheat
Chapter
Section
Page
6
1
6
- The signal for an external fault is given to a programmable digital
input.
(reaction of the drive see parameter Pn.20)
- The adjusted Watchdog-time (parameter ud.8) of the serial
communication was exceeded.
(reaction of the drive see parameter Pn.23)
- At setpoint direction forward terminal F (rotation release forward)
is not active.
(reaction of the drive see parameter Pn.24)
- At setpoint direction reverse terminal R (rotation release reverse)
is not active.
(reaction of the drive see parameter Pn.24)
- The temperature monitoring of the motor has tripped and the pre-
warning time (Pn.16) is active.
(reaction of the drive see parameter Pn.25)
- The temperature monitoring of the frequency inverter has tripped
and the prewarning time (10 s) is active.
(reaction of the drive see parameter Pn.26)