4.2 Password
Structure
4.2.1
Password Levels
©
KEB Antriebstechnik, 1998
All Rights reserved
The KEB COMBIVERT is provided with extensive password protection. The different
passwords are used to
- change the operating mode
- set a write protection
- activate the Service-Mode
- switch to the Drive-Mode
Depending on the actual operating mode the password can be entered in following
parameters
The parameter value of the above parameters shows the actual password level.
Following indications are possible:
CP - read only
CP - on
CP - Service
Application
Drive-Mode
Name: Basis
KEB COMBIVERT F4-F
Operation
when the CP-Mode is active
when the applicatioan mode is active
Only the Customer-parameter
group is visible, exept for CP .0 all
parameters are in the read-only
status (see Chapter 4.3).
Only the Customer-parameter
group is visible. All parameters can
be changed.
Like CP-on, but the parameter
identification is indicated according
to the original parameter (see
Chapter 4.3).
All application parameters are
visible and can be changed. The
CP-parameters are not visible.
The Drive-Mode is a special
operating mode, here the unit can
be put into operation via the
operator (see Chapter 4.4).