KEB COMBIVERT F4-F Applications Manual page 162

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Functional Description
6.5.18.a Torque limit higher than max. torque
-10V
6.5.18.b Torque input via REF1 with Offset 20% (An.4)
-10V
Chapter
Section
Page
6
5
16
Torque
Torque limit CS.6
Max. torque dr.10
-5V
Torque
Max. torque dr.10
Torque limit CS.6
10% CS.6
-5V
Date
Name: Basis
KEB COMBIVERT F4-F
11.05.99
Motor Data and Controller Adjustment
5V
Max. torque dr.10
Torque limit CS.6
5V
Torque limit CS.6
Max. torque dr.10
REF1
10V
REF1
10V
©
KEB Antriebstechnik, 1999
All Rights reserved