KEB COMBIVERT F4-F Applications Manual page 47

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

CP - Parameter
Actual Torque Display
Speed Reference Display
Acceleration Time
©
KEB Antriebstechnik, 1998
All Rights reserved
Displays the actual torque in newtonmeter. During open-loop operation (CP .32 = 0)
value 0 is always shown.
Resolution: 0,1 Nm
max. tolerance: approx. ±30 % in base speed range (see page 4.3.4)
(In the field weakening range larger tolerances are possible)
Displays the speed reference at the output of the ramp generator in rpm.
When the modulation is switched off the setpoint 0 rpm is displayed.
Resolution: 0,5 rpm
positive speed:
direction of rotation "forward"
negative speed:
direction of rotation "reverse"
n
[rpm]
Analog Setpoint Input
acceleration time
Defines the time needed to accelerate from 0 to 1000 rpm. The actual acceleration
time is proportional to the speed change (D n).
Adjustment Range:
Resolution:
Factory setting:
Customer setting
n [rpm]
1000
800
∆ n
300
∆ t
0
0,5
1
1,5
CP.7
Example:
The drive should accelerate from 300 rpm to 800 rpm in 1 s.
∆ ∆ ∆ ∆ ∆ n
= 800 rpm - 300 rpm = 500 rpm
∆ ∆ ∆ ∆ ∆ t
= 1 s
∆ t
CP.7 =
x 1000 rpm
∆ n
Name: Basis
KEB COMBIVERT F4-F
Operation
t [s]
0...320
s
0,01
s
2,0
s
________
s
∆ n
speed change
∆ t
acceleration time for ∆ n
CP.7 =
t [s]
2
1 s
=
x 1000 rpm = 2 s
500 rpm
Date
15.12.98
ANTRIEBSTECHNIK
∆ t
x 1000 rpm
∆ n
Chapter
Section
Page
7
4
3
7
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents