KEB COMBIVERT F4-F Applications Manual page 46

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Operation
Status Display
Apparent Motor Current
Max. Apparent Motor Current
Chapter
Section
Page
4
3
6
Shows the actual operating state of the inverter. Possible displays and their meaning:
(Further state messages see chapter 6.1.5)
no Operation
Forward
Acceleration
Forward
deceleration
reverse
Acceleration
reverse
deceleration
Forward
constant
reverse
constant
Base-Block
Time
external
A
b
fault
n
o
r
m
a
Prohibited
l
rotation
S
forward
t
o
p
Prohibited
p
i
rotation
n
reverse
g
Displays the actual apparent current in ampere.
Resolution: 0,1 A
max. tolerance: approx. ±10 %
Displays the maximum apparent motor current, which is measured during operation.
The display is in ampere.
During operation, using UP (
peak value is deleted when the unit is POWER OFF.
Resolution: 0,1 A
max. tolerance: approx. ±10 %
Date
Name: Basis
15.12.98
KEB COMBIVERT F4-F
– Control release (terminal X2.1) not activated
– Modulation off
– Output voltage = 0 V/drive uncontrolled
Drive accelerates forward
Drive decelerates forward
Drive accelerates in reverse
Drive decelerates in reverse
Drive runs with constant speed and forward
Drive runs with constant speed and reverse
The Base-Block-Time (motor suppression time) runs
out. The power transistors are locked.
The external fault is triggered (terminal X2.7).
The drive's response to external errors is adjusted
in parameter CP.15.
Rotation release on terminal X2.3 is missing:
Drive does not start with positive setpoint and/or
decelerates until standstill. See also parameter CP.35
Rotation release on terminal X2.4 missing:
Drive does not start with negative setpoint and/or
decelerates until standstill. See also parameter CP.35
) or DOWN (
) you can reset the peak value. The
©
KEB Antriebstechnik, 1998
All Rights reserved
CP - Parameter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents