Functional Description

6.3.9 Input Status (ru.16)

Chapter
Section
Page
6
3
8
The input status shows the logic state of the digital inputs which are set internally to
further processing. At that it is irrelevant whether the external terminals are active or
not. If an input is set the corresponding value according to the following table is
displayed. If several inputs are set then the sum of the decimal values is displayed.
Terminal
Name
X2.1
X2.2
X2.3
X2.4
X2.5
X2.6
X2.7
-
-
-
-
ST and I5 are triggered ➭ displayed value = 1+4 = 5
Example:
Date
Name: Basis
02.03.99
KEB COMBIVERT F4-F
Function
ST
control release
I4
prog. input 4
I5
prog. input 5
I6
prog. input 6
I1
prog. input 1
I2
prog. input 2
I3
prog. input 3
IA
internal input A
IB
internal input B
IC
internal input C
ID
internal input D
Digital In- and Outputs
Decimal Value ru.16
1
2
4
8
16
32
64
256
512
1024
2048
©