CP - Parameter
Change Encoder 1 Rotation
Reaction to Limit Switch
©
KEB Antriebstechnik, 1998
All Rights reserved
Adjusts the direction of rotation of the encoder.
Adjustment Range:
Resolution:
Factory setting:
Customer setting
0
=
track not exchanged
1
=
track exchanged
This parameter determines the reaction of the drive, to terminal X2.3 (F) and/or X2.4
(R). These terminals can be programmed as software limit switches. The reaction of
the drive is shown in the table below.
Adjustment Range:
Resolution:
Factory setting:
Customer setting:
Value
Error / Status
massage
0
E.PrF
E.Prr
1
A.PrF
A.Prr
2
A.PrF
A.Prr
3
A.PrF
A.Prr
4
A.PrF
A.Prr
5
A.PrF
A.Prr
6
keine
Quick stop
Name: Basis
KEB COMBIVERT F4-F
Operation
0...1
1
0
________
0...6
1
6
________
Response of the drive
modulation immediately switched off
! To restart remove error and activate Reset !
quick stop / modulation switched off
after speed 0 is reached
! To restart remove error and activate Reset !
quick stop / holding tourqe at speed 0
! To restart remove error and activate Reset !
modulation immediately switched off
! Automatic restart, when error is no longer
present !
quick stop / modulation switched off
after speed 0 is reached
! Automatic restart, when error is no longer
present !
quick stop / holding tourqe at speed 0
! Automatic restart, when error is no longer
present !
no effect on the drive
! Fault is ignored !
⇒ ⇒ ⇒ ⇒ ⇒
deceleration at the torque limit (CP.9)
Date
15.12.98
ANTRIEBSTECHNIK
Chapter
Section
Page
21
4
3
21
4

Hide quick links: