KEB COMBIVERT F4-F Applications Manual page 183

Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

Special Functions
Positioning without 'Target window reached' signal (i.e. no switching condition programmed on value 30: 'Target
window reached' ) :
The same function as before but in addition to the condition actual speed smaller speed hysteresis the status
'rFP:positioning can be started' must be achieved. In this mode the speed setting has no function.
Speed hysteresis LE.37
Start positioning
Actual speed < speed hysteresis
Brake handling at activated positioning with 'Target window reached'-signal:
With the signal 'Target window reached' the brake delay time starts. the speed hysteresis has no function in this mode.
Start positioning
Target window reached
©
KEB Antriebstechnik, 1999
All Rights reserved
Release time
Actual speed
Brake control
'rFP' positioning
can be started
Modulation on
Release time
Actual speed
Brake control
Modulation on
Name: Basis
KEB COMBIVERT F4-F
Functional Description
LE.67
LE.67
ANTRIEBSTECHNIK
Delay time
Application
LE.66
time LE.68
Delay time
Application
LE.66
time LE.68
Date
Chapter
Section
6
8
19.05.99
6
Page
5
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents