Sntp Client Configuration - Siemens SCALANCE X-300 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

4.4.10.2

SNTP Client Configuration

Time-of-day synchronization with SNTP
SNTP (Simple Network Time Protocol) is used for synchronizing the time in the network. The
appropriate frames are sent by a server in the network. An IE switch logs on as client with
this server as recipient of time-of-day frames.
The "SNTP Client Configuration" screen appears if you click the "SNTP Client" submenu.
Figure 4-42
SNTP Mode
You can choose between the following protocol types:
● Poll
If you select this type of protocol, you will need to set the SNTP server IP address.
You can modify the following settings:
SNTP Server Port, Init poll interval, Poll interval, Time Zone Offset.
● Listen
If you select this protocol type, you can also select a time zone offset in addition to the
time received from the server.
Note
Time Zone Offset
The time zone offset setting is in the Agent Time Configuration (Page 116) menu.
SNTP Server IP Address
Enter the IP address of the SNTP server whose frames will be used by an IE switch to
synchronize the time of day.
SNTP Server Port
Enter the port via which the SNTP server is available.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
SNTP Client Configuration
4.4 The Agent menu
119