Siemens SCALANCE X-300 Configuration Manual page 369

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

ifOperStatus
ifLastChange
ifInErrors
ifOutErrors
Port Indexes
With SNMP, you cannot specify port identifiers in the format "Slot.Port". SNMP addresses
the ports with interface indexes. To change the settings of a port over SNMP, use the AG
index. Changes made using the CLI or WBM, can be seen over SNMP only on the AG
interfaces. If traps are used, remember that due to the architecture, the AP interfaces are
specified in the SNMP bindings of, for example, link up traps. The following tables show how
the interface indexes are assigned to the ports.
Port tables for SCALANCE X-300, X408-2 and X414-3E
● Example of a port table (applies to SCALANCE X-300 / X408-2 / X-414-3E):
The "ifOperStatus.51380225" variable determines the operating state (up, down etc.) of
port 1 of the IE switch.
Note
The available number of ports is decided by the device version
Ports are available or not depending on the device version, for example on the device X-306-
1LD FE, there are only 7 ports available.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Variables
Access rights
Read only
Read only
Read only
Read only
B.1 MIB variables of a SCALANCE X300/X400
Description
The current operating status of the Ethernet port.
The following values are possible:
up(1)
down(2)
testing(3)
unknown(4)
dormant(5) [waits for external action]
notPresent(6)
lowerLayerDown(7)
The testing(3) status indicates that no user data is
transported.
Data type: Integer
Length of time for which the selected port has
been operating in the current status. The value is
shown in hundredths of a second.
Data type: TimeTicks
Number of received packages that were not for-
warded to higher protocol layers because of an
error.
Data type: Counter
Number of packages that were not sent because
of an error.
Data type: Counter