Note
If passive listening is enabled, the IE switch forwards (R/M)STP configuration frames
transparently even when (R/M)STP is disabled for it. If it recognizes a topology change
frame, it reduces the aging time for a limited period so that the node list is updated more
quickly.
Once this period has elapsed, the original aging time applies again.
Enhanced Passive Listening Compatibility
If you enable Enhanced Passive Listening Compatibility, TCN (Topology Change
Notifications) frames will be sent via RSTP edge ports. In conjunction with the "Auto Edge
Port" function (section Spanning Tree Port Parameters (Page 199)), this parameter is
necessary to link (R)STP networks with HRP rings. Otherwise no TCN frames will be sent
via edge ports; this is, however, necessary for the passive listening function on ring nodes
(refer to the operating instructions of the relevant switch).
RSTP Big Network Support
If you enable RSTP Big Network Support, large RSTP rings with up to 80 bridges are
supported.
Syntax of the Command Line Interface
Table 4- 37
info
aging [E|D]
agetime [seconds]
mirror [E|D]
plisten [E|D]
oversize [E|D]
gmrp [E|D]
igmp [E|D]
gvrp [E|D]
opt82 [E|D]
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
Switch Configuration - CLI\SWITCH>
Command
Shows the current settings in the Switch
menu.
Enables/disables aging functionality.
Specifies the aging time in seconds.
Enables/disables port mirroring.
Enables/disables passive listening.
Enables/disables the oversize mode
function.
Enables/disables GMRP functionality for
all IE switch ports.
Enables/disables IGMP functionality for
all IE switch ports.
Enables/disables GVRP functionality for
all IE switch ports.
Enables/disables the DHCP option 82.
Description
4.5 The Switch menu
Comment
-
Administrator only
Default value: Enabled
Administrator only
The default is 30 seconds
(applies to the SCALANCE
X408-2)
or 40 seconds (applies to the
SCALANCE X414-3E).
Administrator only
Administrator only
Administrator only
Administrator only
Administrator only
Administrator only
Administrator only