Siemens SCALANCE X-300 Configuration Manual page 349

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Value (hexadecimal)
0x001E
0x001F
0x0020 – 0x002D
0x002E
0x002F – 0x0035
0x0036
0x0037 – 0xFFFF
DomainBoundary
Specifies which multicast addresses are blocked.
MulticastBoundary
The individual bits of the DWord variables specify which of the 32 first RT_CLASS_2
multicast addresses (from 01-0E-CF-00-02-00 bis 01-0E-CF-00-02-1F) is blocked.
Bit
0
...
31
LinkState
LinkState.Link
Value (hexadecimal)
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08 - 0xFF
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Meaning
1000BASETFD
10GigBASEFX
Reserved
100BASELX10
Reserved
100BASEPXFD
Reserved
Value
Meaning
1
The multicast MAC address 01-0E-CF-00-02-00 will be blocked.
0
The multicast MAC address 01-0E-CF-00-02-00 will not be
blocked.
1
The multicast MAC address 01-0E-CF-00-02-xx will be blocked.
0
The multicast MAC address 01-0E-CF-00-02-xx will not be
blocked.
1
The multicast MAC address 01-0E-CF-00-02-1F will be blocked.
0
The multicast MAC address 01-0E-CF-00-02-1F will not be
blocked.
Meaning
Reserved
Up (ready to send packets)
Down
Testing (no user data is transported)
Unknown (status cannot be identified)
Dormant (waits for external action)
Not present
LowerLayerDown
Reserved
PROFINET IO functionality
6.4 Data record 0x802A (PDPortDataReal)
349