Siemens SCALANCE MM900 Series Compact Operating Instructions

Simatic net. industrial ethernet switches
Hide thumbs Also See for SCALANCE MM900 Series:

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
SCALANCE MM900
Compact Operating Instructions
11/2019
A5E02630805-16
Introduction
Safety notes
Recommendations on
network security
Device description
Assembling
Connecting
Technical data
Dimension drawings
Approvals
Appendix
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE MM900 Series

  • Page 1 Introduction Safety notes Recommendations on network security SIMATIC NET Device description Industrial Ethernet switches SCALANCE MM900 Assembling Connecting Compact Operating Instructions Technical data Dimension drawings Approvals Appendix 11/2019 A5E02630805-16...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................5 Safety notes..............................9 Recommendations on network security......................11 Device description ............................15 Product overview........................15 Product properties and device views ..................20 4.2.1 MM991-2 (BFOC)........................20 4.2.2 MM991-2FM (BFOC) ......................20 4.2.3 MM991-2LD (BFOC) ......................21 4.2.4 MM991-2 (SC) ........................21 4.2.5 MM991-2LD (SC) ........................22 4.2.6 MM991-2LH+ (SC) ........................22 4.2.7...
  • Page 4 Table of contents Dimension drawings ...........................53 Approvals..............................57 Appendix..............................65 EMC-compatible installation of electrical Industrial Ethernet or PROFIBUS cabling .....65 Equipotential bonding......................65 Index................................69 SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 5: Introduction

    Introduction Purpose of the compact operating instructions Based on the compact operating instructions, you will be able to install and connect the MM900 media modules correctly. Validity of these compact operating instructions These compact operating instructions apply to the MM900 product group within the SCALANCE X-300 product line: ●...
  • Page 6 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 7 Feed under https://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity) Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
  • Page 8 Introduction SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 9: Safety Notes

    Safety notes Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 10 Safety notes SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 11: Recommendations On Network Security

    Industrial Security (https://www.siemens.com/ industrialsecurity) website. ● Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you require to use the device. ● Restrict access to the management of the device with rules in an access control list (ACL).
  • Page 12 Recommendations on network security ● The option of VLAN structuring provides protection against DoS attacks and unauthorized access. Check whether this is practical or useful in your environment. ● Use a central logging server to log changes and accesses. Operate your logging server within the protected network area and check the logging information regularly.
  • Page 13 Recommendations on network security Secure/non-secure protocols ● Avoid or disable non-secure protocols, for example Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non- secure protocols on the device with caution. ● Check whether use of the following protocols and services is necessary: –...
  • Page 14 Recommendations on network security SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 15: Device Description

    Device description Product overview Note Type designation and labeling of a media module differ Example: The device with article number 6GK5 992‑2AS00‑8AA0 is called "MM992‑2SFP", the labeling on the device is "9922AS". The labeling on the devices is shown in bold in the following table following the [article numbers]. Note Media modules for SFP transceivers Only the media modules MM992-2SFP andMM992-2SFP (C) may be fitted with approved SFP...
  • Page 16: A5E02630805

    Device description 4.1 Product overview Media module Properties Article number Labeling on the device MM991-2FM (BFOC) 2 x 100 Mbps, BFOC port optical, for glass FO cable (multimode) with 6GK5 991-2AB01-8AA0 diagnostics up to max. 5 km 9912AB MM991-2LD (BFOC) 2 x 100 Mbps, BFOC port optical, for glass FO cable (single mode), up to 6GK5 991-2AC00-8AA0 max.
  • Page 17 Device description 4.1 Product overview Interface Property SC RJ port 100 Mbps POF or PCF BFOC port 100 Mbps multimode FO cable with diagnostics M M 9 9 2 - 2 1000 Mbps Number of ports Interface Interface Property RJ-45 port electrical 10/100/1000 Mbps without securing collar RJ-45 port electrical 10/100/1000 Mbps with securing collar M12 connection electrical 10/100/1000 Mbps RJ-45 port electrical 10/100/1000 Mbps with securing collar (up to max.
  • Page 18 Device description 4.1 Product overview Media module IEEE 802.3 standard MM992-2LH+ (SC) 1000Base-LX MM992-2ELH (SC) 1000Base-LX Note Use media modules only in an approved modular device ("M") Use an MM900 media module only in a device equipped with suitable slots for such modules. Example: X308-2M.
  • Page 19: Approvals

    Device description 4.1 Product overview Possible attachment Figure GE M12 connector electrical SFP transceivers Only the SFP media module MM992-2SFP may be fitted with approved SFP transceivers. The SFP me‐ dia module can be fitted with up to two SFPs. Unpacking and checking WARNING Do not use any parts that show evidence of damage...
  • Page 20: Product Properties And Device Views

    Device description 4.2 Product properties and device views Product properties and device views 4.2.1 MM991-2 (BFOC) Possible attachments The MM991-2 (BFOC) media module has the following: ● 2 x 100 Mbps, BFOC port optical (multimode, glass) up to max. 5 km Figure 4-1 MM991-2 (BFOC) [9912AB] [Device labeling in square brackets]...
  • Page 21: Mm991-2Ld (Bfoc)

    Device description 4.2 Product properties and device views 4.2.3 MM991-2LD (BFOC) Possible attachments The MM991-2LD (BFOC) media module has the following: ● 2 x 100 Mbps, BFOC port optical, (single mode glass), up to max. 26 km Figure 4-3 MM991-2LD (BFOC) [9912AC] [Device labeling in square brackets] 4.2.4 MM991-2 (SC)
  • Page 22: Mm991-2Ld (Sc)

    Device description 4.2 Product properties and device views 4.2.5 MM991-2LD (SC) Possible attachments The MM991-2LD (SC) media module has the following: ● 2 x 100 Mbps, SC port optical, (single mode glass), up to max. 26 km Figure 4-5 MM991-2LD (SC) [9912AF] [Device labeling in square brackets] 4.2.6 MM991-2LH+ (SC)
  • Page 23: Mm991-2P (Sc Rj)

    Device description 4.2 Product properties and device views 4.2.7 MM991-2P (SC RJ) Possible attachments The MM991-2P (SC RJ) media module has the following: ● 2 x 100 Mbps SC RJ ports optical for Plastic Optical Fiber (POF) up to max. 50 m or Polymer Cladded Fiber (PCF) up to max.
  • Page 24: Mm992-2Cu

    Device description 4.2 Product properties and device views 4.2.8 MM992-2CU Possible attachments The MM992-2CU media module has the following: ● 2 x 10/100/1000 Mbps, RJ-45 port electrical without securing collar Figure 4-8 MM992-2CU [9922SA] [Device labeling in square brackets] Note For connection to electrical networks note the information in Appendix A.1 and A.2.
  • Page 25: Mm992-2Vd

    Device description 4.2 Product properties and device views 4.2.10 MM992-2VD Possible attachments The MM992-2VD media module has the following: ● 2 x 10/100/1000 Mbps, RJ-45 ports electrical with securing collar ● Additional two-wire transfer function (variable distance) for establishing Ethernet connections even using cables that do not conform to Ethernet.
  • Page 26: Mm992-2 (Sc)

    Device description 4.2 Product properties and device views RJ-45 connectors PROFIBUS cable Pin assignment Color Wire color White Blue Note Using PROFIBUS standard cable GP If you use a PROFIBUS standard cable GP, the wires must be stripped before they are inserted in the FC connector.
  • Page 27: Mm992-2Ld (Sc)

    Device description 4.2 Product properties and device views 4.2.12 MM992-2LD (SC) Core statement The MM992-2LD (SC) media module has the following: ● 2 x 1000 Mbps, SC port optical, (single mode glass), up to max. 10 km Figure 4-12 MM992-2LD (SC) [9922AM] [Device labeling in square brackets] 4.2.13 MM992-2LH (SC)
  • Page 28: Mm992-2Lh+ (Sc)

    Device description 4.2 Product properties and device views 4.2.14 MM992-2LH+ (SC) Possible attachments The MM992-2LH+ (SC) media module has the following: ● 2 x 1000 Mbps, SC port optical, (single mode glass), up to max. 70 km Figure 4-14 MM992-2LH+ (SC) [9922AP] [Device labeling in square brackets] 4.2.15 MM992-2ELH (SC)
  • Page 29: Mm992-2M12

    Device description 4.2 Product properties and device views 4.2.16 MM992-2M12 Possible attachments The MM992-2M12 media module has the following: ● 2 x 10/100/1000 Mbps, GE M12 connector electrical Figure 4-16 MM992-2M12C [9922HA] [Device labeling in square brackets] Note For connection to electrical networks note the information in Appendix (A.1, A.2 and A.3) 4.2.17 MM992-2SFP / MM992-2SFP (C) Note...
  • Page 30 Device description 4.2 Product properties and device views SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 31: Assembling

    Assembling Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 40 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 40 ℃.
  • Page 32 Assembling 5.1 Safety notices for installation WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
  • Page 33: Installation And Removal Of Media Modules

    Assembling 5.2 Installation and removal of media modules NOTICE Warming and premature aging of the IE switch due to direct sunlight Direct sunlight can heat up the device and can lead to premature aging of the IE switch and its cabling. Provide suitable shade to protect the IE switch against direct sunlight.
  • Page 34 Remove the protective caps only immediately before you use the plug-in connection. NOTICE Use only approved SFPs If you use components not approved by Siemens AG, in particular SFPs, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 35 Assembling 5.2 Installation and removal of media modules Note Use media modules only in an approved modular device Use an MM900 media module only for a device equipped with suitable slots for such modules. Example: X308-2M. The names and labeling of the media modules differ ●...
  • Page 36 Assembling 5.2 Installation and removal of media modules Select the required slot on the device (for example, X308-2M). Remove the dummy cover. Pull out the handle on the selected media module. Place the media module in the guide rails of the device slot.
  • Page 37 Assembling 5.2 Installation and removal of media modules Push the handle back into the media module. This locks the media module in the device. Insert the connectors. Removing a media module CAUTION Risk of burns due to the high temperature of the module housing Before removing an MM900 media module, turn the switch off and allow the device to cool down first.
  • Page 38: Sfp Installation In Sfp Media Module

    NOTICE Use only approved SFPs If you use SFPs that are not approved by Siemens AG, there is no guarantee that the device will function according to the specification. If you use unapproved SFPs, this can lead to the following problems: ●...
  • Page 39: Removing An Sfp

    Assembling 5.3 SFP installation in SFP media module Select the required SFP media module in the slot of the device. (Example: X-308-2M, slot 2) Insert the SFP with the clip closed in the SFP media module. Notice: Closing the clip after insertion does not lock the device in the rack.
  • Page 40 Assembling 5.3 SFP installation in SFP media module SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 41: Connecting

    Connecting Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present.
  • Page 42: Connecting A Media Module

    Connecting 6.2 Connecting a media module NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Take the following precautions to avoid functional impairments: ●...
  • Page 43: Technical Data

    Technical data Note Validity of the technical specifications All the technical specifications described in this section that are not specific to a product version, apply to the MM900 media module. Construction, installation and environmental conditions Table 7-1 Construction Dimensions (W x H x D) 60 ×...
  • Page 44 Technical data 7.1 Construction, installation and environmental conditions Type Installation Without me‐ MM992-2CUC MM991-2LH+ Media module Media module location dia module MM992-2CUC (C) (SC) MM992-2SFP MM992-2SFP MM992-2CU MM992-2LH with SFP trans‐ with SFP transceiver MM992-2M12 (C) (SC) ceiver SFP991-1LH+ MM992-2VD MM992-2LH+ SFP991-1 SFP992-1+...
  • Page 45: Connectors And Electrical Data

    Technical data 7.2 Connectors and electrical data The permitted operating temperature depends on how the mounting device was installed. The installation is horizontal if the device labeling is from left to right. With a vertical installation, the device labeling is rotated through 90°. Table 7-3 Operating temperature with media module MM991-2P Type...
  • Page 46 Technical data 7.2 Connectors and electrical data Media module Interfaces MM991-2LD (SC) 2 x 100 Mbps, SC ports optical, single mode FO cable, up to max. 26 km MM991-2LH+ (SC) 2 x 100 Mbps, SC ports optical, single mode FO cable, up to max.
  • Page 47 Technical data 7.2 Connectors and electrical data Media module Current consumption Effective power loss MM992-2LD (SC) 80 mA 1.95 W MM992-2LH (SC) 90 mA 2.11 W MM992-2LH+ (SC) 100 mA 2.42 W MM992-2ELH (SC) 110 mA 2.75 W Table 7-8 Electrical data: Current consumption and power loss II MM992-2SFP with Current consumption...
  • Page 48: Cable Lengths

    Technical data 7.3 Cable lengths Media module Transmitter output (optical) Receiver input min. [dBm] max. [dBm] Sensitivity min. [dBm] Input power max. [dBm] MM992-2 (SC) -9.5 MM992-2 (C) (SC) -9.5 MM992-2LD (SC) -9.5 MM992-2LH (SC) MM992-2LH+ (SC) MM992-2ELH (SC) MM992-2SFP You will find further information in the compact operating instructions "Transceiver SFP/SFP +".
  • Page 49 Technical data 7.3 Cable lengths Media module Cable Permitted cable length MM992-2VD (with VD) IE FC TP standard cable GP 4X2 (24 0 to 500 m at 100 Mbps AWG) with IE FC RJ-45 plug 4x2 IE FC TP standard cable GP 2x2 0 to 300 m at 100 Mbps.
  • Page 50 Technical data 7.3 Cable lengths Media module Fiber-optic cable type Max. permitted Attenuation cable length MM991-2FM 50/125 µm 5 km ≤1 dB/km at 1300 nm;1200 MHz*km; maximum insertion loss (BFOC) multimode fiber 0.5 dB; 9 dB max. permitted FO cable attenuation at 3 dB link power margin 62.5/125 µm multi‐...
  • Page 51: Other Properties

    Technical data 7.4 Other properties Copper / fiber-optic cables Table 7-14 Permitted cable lengths (copper cable/fiber-optic cable) for the SFP media module Media module Max. permitted cable length MM992-2SFP Depending on the SFP transceiver used. You will find further information in the compact operating instructions "Transceiver SFP/SFP+". Attenuators Transceivers of the types LH, LH+, ELH and ELH200 are designed for long distances and therefore send more power than they can receive.
  • Page 52 Technical data 7.4 Other properties Device version (power supply) MTBF MM991-2 (BFOC) > 140 years MM991-2 (SC) MM991-2FM (BFOC) > 135 years MM992-2 (C) (SC) MM991-2LD (BFOC) > 115 years MM991-2LD (SC) MM992-2LD (LD) MM991-2LH+ (SC) > 105 years MM992-2LH (SC) MM992-2LH+ (SC) MM992-2ELH (SC) >...
  • Page 53: Dimension Drawings

    Dimension drawings Note The following dimension drawings are available for the MM900 product group. Figure 8-1 MM900 dimension drawing 1: Electrical RJ-45 ports with securing collar Figure 8-2 MM900 dimension drawing 2: Electrical RJ-45 ports without securing collar SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 54 Dimension drawings Figure 8-3 MM900 dimension drawing 3: BFOC ports Figure 8-4 MM900 dimension drawing 4: Optical SC ports SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 55 Dimension drawings Figure 8-5 MM900 dimension drawing 5: SFP media module Figure 8-6 MM900 dimension drawing 6: M12 ports electrical Figure 8-7 MM900 dimension drawing 7: SC RJ ports optical SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 56 Dimension drawings SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 57: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15303/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 58 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15303/cert) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially...
  • Page 59 Approvals Permitted types of protection The following types of protection are possible: ● nA ATEX classification: II 3G Ex nA IIC T4 Gc Certificate no.: KEMA 07ATEX0145 X The products meet the requirements of the following standards: – EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 60 Approvals The following types of protection are possible: ● nA IECEx classification: Ex nA IIC T4 Gc Certificate no.: DEK 14.0025X The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 61 Approvals Applied standards: ● EN 61000‑6‑2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments ● EN 61000‑6‑4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid EC declaration of conformity.
  • Page 62 Approvals Report no. E115352 cULus approval for industrial control equipment cULus Listed IND. CONT. EQ. Underwriters Laboratories Inc. complying with ● UL 508 ● CSA C22.2 No. 142-M1987 Report no. E85972 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc.
  • Page 63 Approvals Railway approval Media modules with the supplement (C) in the type name have varnished printed circuit boards (conformal coating) and meet the requirements of the railway standard: ● EN 50155 "Railway applications - Electronic equipment used on rolling stock". Note When used on railway stock, a stabilized power supply must be used to comply with EN50155.
  • Page 64 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/...
  • Page 65: Appendix

    Appendix EMC-compatible installation of electrical Industrial Ethernet or PROFIBUS cabling The Industrial Ethernet / PROFINET system manual "Passive network components" prescribes the use of fiber-optic cables for cabling between buildings and/or external facilities because there may be large potential differences between nodes. If IE FC or PROFIBUS FC cables are used for such applications, the same rules apply as when installing cables indoors.
  • Page 66 Appendix A.2 Equipotential bonding When and why is equipotential bonding necessary? Several good reasons for equipotential bonding are listed below: ● Devices with a grounded interface can be damaged by potential differences. ● The shield of the PROFIBUS cable must not be used for equipotential bonding. This is, however, the case if parts of the system connected by the cable shield are connected to different grounding points.
  • Page 67 Appendix A.2 Equipotential bonding In systems in which no equipotential bonding is possible, the current flow via the shield needs to be prevented. Despite this, to be able to use the shield properties of the cable note the following: ● Contact the shield at one end with low resistance. ●...
  • Page 68 Appendix A.2 Equipotential bonding SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...
  • Page 69: Index

    Index Approvals, 57 Attenuation, 51 Attenuator, 51 CE mark, 57 GI-PCF, 51 Glossary, 6 Power supply Media modules, 42 Safety notices for installation, 31 general, 9 Use in hazardous areas, 9, 31, 41 when connecting up, 41 Scope of delivery, 19 SIMATIC NET glossary, 6 System manual, 33, 64 SCALANCE MM900...
  • Page 70 Index SCALANCE MM900 Compact Operating Instructions, 11/2019, A5E02630805-16...