Configuration using Web Based Management and Command Line Interface
4.2 The System menu
Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the IE switch and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
modules or extenders, it can, however, change if you update the firmware.
File System
Displays the type of file system on the C-PLUG.
File System Size
Displays the maximum storage space of the file system on the C-PLUG.
File System Usage
Shows the storage space being utilized in the C-PLUG file system.
C-PLUG Info String
Here, you will see all the additional information about the device that used the C-PLUG
during previous operation, for example, order number, type designation, and the versions of
the hardware and software.
Modify C-PLUG, Modify
You can only make settings in this box if you are logged in as "Administrator". Here, you
decide how you want to change the content of the C-PLUG. The following alternatives are
possible:
● Copy internal Configuration to C-PLUG and Restart

 T he configuration in the internal flash memory of the IE switch is copied to the C-PLUG;
this is followed by a restart.
This function is required in the following important use case: The IE switch has started up
with a C-PLUG containing a bad configuration or a configuration different from the IE
switch. If you have not yet made any configuration changes after starting up the device,
you can use this function to overwrite the content of the C-PLUG with the original device
configuration.
● Copy default Configuration to C-PLUG and Restart

 A configuration with all the factory default values is stored on the C-PLUG. This is
followed by a restart in which the IE switch starts up with these default values.
● Clean C-PLUG (Low Level Format, Configuration lost)

 D eletes all data on the C-PLUG and starts a low-level formatting function. This is not
followed by an automatic restart and the IE switch displays an error. You can clear this
error status by restarting or removing the C-PLUG.
Select the necessary entry in the drop-down list and click "Modify, to change the C-PLUG as
required.